IMPORTANT
Before operating the unit read the following safety instructions.
Failure to comply with these warnings may result in serious injury or death.
For specific Safety Information relating to the attached engine or motor ensure you read
and understand the manual and instructions supplied by the engine or motor manufacturer.
Fill pump body with water (Nova SP Models Only).
Connect suction hose from pump inlet
(marked with arrow) to supply tank outlet.
Hose must be of non-collapsible, reinforced
construction with a minimum inside diameter
of 19mm.
Ensure all suction hose connections are
airtight otherwise performance may be
affected. Keep suction hose as short as possible
and avoid unnecessary bends.
Connect pressure spray hose from pump outlet (marked with arrow) to spray equipment. Ensure all pressure spray hose connections are airtight otherwise performance may be affected.
Connect hose from bypass ball valve to supply tank.
Fill supply tank with spraying liquid. (Nova NP Model only - ensure fluid level in supply tank is above highest point of suction hose).
Open the bypass ball valve completely, run the pump at slow speed and allow the pump to prime itself. (removing air from the system).
The unit is now ready for on-going use. Set the bypass ball valve open halfway, this will ensure the mechanical seal is lubricated at all times.